GDPQ-5000 Power Quality Analyser
GDPQ-5000 Potentia Quality Analyser est instrumentum comprehensivum a nostro comitatu diligenter enucleatum et specialiter destinatum ad campum experimentum trium graduum, multi-muneris et intelligentis, operatio hominis machinalis concisa.Facile est uti, magnas LCD screen propono, alta resolutio, interfacies tam in Sinica quam Anglica, structurae conchae probationis et cetera.Simul simul metiri potest currentis currentis 4-canalis (ABC tria phase et neutrius currentis filum), 4-alvei intentionis (ABC trium-phasrum intentionis et lineae neutrae intentionis ad terram), apicem valorem currentis intentionis, maximi/minimi valoris supra tempus. , factor inaequalitatis trium phase, breve tempus intentionum vibrantium, factor K transformator, potentia activa, potentia reactiva, potentia apparentis, factor potentiae et obsessio potentiae factor, potentia activa, potentia reactiva, potentia apparentis, tota harmonica depravatio et harmonica, etc;Praesta waveform real-time, ratio harmonica vectis chartis voltationis currentis;Dynamice capiunt instantaneae mutationis voltage currentis, vigilantia currentis inceptiva, vigilantia potentiae parametri et album terrorem generant, chartulam inclinationis generare per longum tempus recordum testium datarum.
GDPQ-5000 Potentia qualitas analysris adhibet DSP + ARM duplex processus architectura, DSP usus est ad collectionem notitiarum et processus algorithmi, ARM usus est ad protocollum communicationis et processus interfaciei viri machinae;Analogia signum acquisitio est ab 2 fragmentis AD7655 de ADI comitatu.Resolutio pro AD7655 est 16 frenum et est 4 canalis synchroni sampling.Praecipua rate sampling 1 MSPS attingere potest, ut subtilitatem canalis et integritatis informa- tionem curet, neque ullas in craticulas mutationes transientes fallat, verius potest detegere fluctuantem fluctuationem et stillantem vehementius ac fluctuantem instantaneum interrumpendum. ;DSP laborans frequentia super 200 MHZ, ut tempestive vigilantia potentiae eget ac dynamice accommodare possit sampling frequentiam ad cognoscendam synchronizationem potestatis frequentiae et sampling frequentiam;Usus 5.6 -inch LCD color velamentum ostentationis, resolutio 640 punctis x 480 dots, cum diversicoloris ostentationis differentia inter parametros phase, waveformes, vector diagram, proportionem harmonicam, utens efficacius et magis intuitivus rempublicam intelligere potest. virtutis malesuada euismod.Memoria in mico constructa 60 coetus emissariorum simul condere potest, 150 circulos voltagenarum transeuntium / figuram fluctuum currentium capientium et 12800 circulos terroris indicem.Exemplar deprehensionis currentis incipientes continue capere potest initium currentis waveformi pro 100 s.Inaedificata in 2G memoria schedulae ad reponendas flecte curvas recordationes, simultaneos viginti parametris (secundum necessitatem eligere potest) notitias colligere pro singulis quinque secundis semel, tabulae curvae inclinatio per 300 dies recondi possunt.
Appellatur etiam Intelligens Tres Phase Potestas Quality Analyser, Multifunctionalis Potestas Quality Analyser, quae simul cum functionibus analyseris harmonici, phase volt-ampere metri;electricum modulum probat.Ad electricitatis industriam, petrochemicam, metallurgiam, ferriviariam, fodiendarum conatum, investigationis scientificae institutionem, metriologicam partem applicat.Praecipue apta analysi et diagnosi comprehensiva in omnes voltage, current, potentiae, potentiae, harmonicae, parametri electrici Phase.
2.1.Munus mensurae
●Waveform real-time ostentationis (4 canales voltage/4 canales currentes).
●Vera RMS valores voltages et excursus.
●The dc tium voltages.
●Apicem venae et bonae intentionis.
●Minimum et maximus medietas cycli RMS currentis et intentionis valoris.
●Phasor icone proponere.
●Mensuratio utriusque harmonica usque ad ordinem 50 .
●Bar chartulae rationes harmonicas currentis et intentionis cuiusque aetatis ostendunt.
●Totalis pravitatis harmonicae (THD).
●Activa, reactiva, apparens potentia, per tempus et cumulativum.
●Activa, reactiva, apparens vis, per tempus et cumulativum.
●Transformator K factor.
●Potestas factorum (PF) et obsessio factorum (DPF vel COSΦ).
●Breve tempus intentione vibrat (PST).
●Tres periodi unbalance (vena et intentione).
2.2.Transiens munus captis
Magna momentanea mutatio potentiae eget parametri voltationis currentis, incluso fluctuationes voltage current, impetus voltage current, copia brevis et interruptio, temporis overvoltatio, impetus currentis et voltatio instantaneae pravitatis currentis.Instrumenta simul reponunt 150 mutatoriae waveformes.
2.3.Satus current magna
Magna impetus currens lineae et satus vena cum electrica apparatu incipitur, adiuva ad facultatem recte designandi.Exhibere possunt curvam RMS ortu/cadens In initio processus, involucrum curvae satus currentis, agitationem 4 canalium venarum et 4 canalium voltage.Recordatio circa 100s post felis, repone curvam voltationem instantaneae et fluctuationis cuiusvis cycli in 100s.
2.4.Trend chart memoria ac repono munus
Omnia examinis parametri fundamentalium testium functiones (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF, W, VAR, VA, PF, COSφ; TANφ), 50 harmonica intentionum, 50 harmonicae currentis.Et flecte curvam crea.Record notitia diu iuxta necessitatem (delectu concurrens 20 parametri ad notas recordandas pro semel in quinque secundis, de CCC diebus scribere potes.).
2.5.Terror munus
Valores limites secundum necessitatem pone, vigilantia valorum sive LUXURIA, si LUXURIA tigillum generabit, ut: voltage, current, inaequalitas, ratio harmonica, frequentia, potentia activa, totali harmonica depravatio.40 diversos terrores configurare potes, unaquaeque caterva diversos parametros vigilantes (including 50 harmonicas, summas 123 parametros diversos) et valores limites, potest etiam brevissimum tempus LUXURICIAE.Stipes potest continere usque ad 12,800 terrores.
2.6.Snapshot munus
Quodvis tegumentum servari potest (snapshot velum), simul automatice commemorat tempus ac modum test.Quales possunt nisi intentione et fluctuatione currenti, chartis harmonicis, diagramma phasorisetc. Maximum of 60 screen snapshot potest salvum facere.
2.7.Communicationis munus
Communicare cum USB per computatrum, programmatio vigilantia potest ostendere waveformi potentiae qualitatis analysin, legere de fluctuatione transeuntis, chart recordationem flecte, terrorem stipes, eenshotsscray et in computer proponere.
2.8.Munus profecta
Usor potest conformationem temporis ac temporis, configurationem veli repugnantis et claritatis, definitionem cuiusque temporis et colorum curvarum.
Electio generis nexus ad ornatum.
Configuratio rationum sensoriis et intentionis hodiernae.
2.9.Auxilium menu
Omnis operationis scaena urgere potest clavem "auxilium" ad informationes talium obtinendas.
3.1.Basis conditio et opus conditio
cInfluence factor | Test item | Basis conditio | operantes conditio |
Mauris tortor | Omnes parametri | (23±2)°C | -10°C~ 40°C |
Relativum humiditas | Omnes parametri | 40%~ 60% | <80% |
Phase-ut-neutrum voltage | Omnes parametri | (100±1%) V | 1.0V~ 1000V |
Phase-ad-tempus voltage | Verum RMS tempus-ad-phase voltage | (200±1%) V | 1.0V~ 2000V |
Current | Verum RMS current | (5±1%)A | 10mA~ 10A |
Network frequentia | Omnes parametri | 50Hz±0.1Hz | 40Hz~ 70Hz |
tempus subcinctus | Activa potentia et active navitas | Cosφ = 1 | Cosφ: 0.2~ 1.0 |
Reactivum potentia et reactivum industria | Sinφ = 1 | Sinφ: 0.2~ 1.0 | |
Harmonic | Omnes parametri | <0.1% | 0.0%~ 100% |
intentione unbalance | Omnes parametri | <10% | 0.0%~ 100% |
Opus voltage de fabrica | Omnes parametri | DC9.8V±0.1V | DC9.5V~ 10.5V |
campus electricus externus; propinquo | Omnes parametri | Vitandum | |
Test situ | Parametris de current related metiri | Fibulae centrum ad filum probata. |
3.2.Generalis specificatio
Potentia copia | Lithium rechargeable altilium sarcina 9.6V, tergum patina. |
Pugna indicator | Pugna symbol ostendit industriam TUBER.Cum intentione facta nimis est humilis, automatic shutdown post 1 minute. |
Potentia consummatio | Vena consumptio normalium test 490 mA, continua operatio per 8 horas. |
Propono modus | LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm. |
Magnitudinem Fibulae | 008B parva fibulae acuta vena: 7.5mm×13mm; |
Instrumentum dimensionum | L×W×H: 240mm×170mm×68 mm. |
Numerus canalium | 4U/4I. |
Phase-ad tempus voltage | 1.0V~2000V. |
Phase-ut-neutrum voltage | 1.0V~1000V. |
Current | 008B Fibulae vena: 10mA~10.0A; |
Frequentia | 40Hz~70Hz. |
Parametri electricitatis | W, VA, Var, PF, DPF, cosφ, tanφ. |
Energy parametri | Wh, Varh, Vah. |
Harmonic | Order 0~50. |
Totalis corruptelam harmonicae | Ordo 0~50, singulis phase. |
Peritus modus | Ita. |
Numerus Transiens records | 150 occidit. |
Voltage flammis | Ita. |
Satus current modus | Ita, 100 seconds. |
III temporibus unbalance | Ita. |
Record | CCC dies (simul XX parametri recordarentur, unum punctum singulis 5 secundis recordarentur). |
Min / Max memoriae valorem | Mensuratio valorum maximorum et minimorum per aliquod temporis spatium. |
Alarm | 40 genera parametri excerpta, 12.800 tigna terrorem ponit. |
Peak | Ita. |
Ostentationem Phasor tabula | Automatarie. |
Facultatem snapshots | LX. |
Menu language | Anglicus |
Communicationis | USB. |
Lorem switching off | Cum expeditionem resonat initiatur vel investigatio vagorum, incursus currentis captio, vel recordatio inclinatio pendente vel in progressu, fabrica automatice mutandi non est. |
Aliis modus test, 15 minuta sine keystrokes, automatice shutdown post promptum 1 minutum. | |
Backlight munus | Etiam noctu et obscuro loco utendum est. |
Pondus | Exercitum: 1.6kg (cum altilium). |
008B parva fibulae acuta vena: 170g×4; | |
Test filum longitudinem voltage | 3m. |
Longitudo current sensorem filum | 2m. |
opus temperatuset humiditatem | -10°C~40°C;infra 80% Rh. |
Repono caliditas et humiditas | -10°C~60°C;infra LXX% Rh. |
Input impedimentum | Impedimentum initus testi intentionis: 1MΩ. |
Noli sustinere voltage | 3700V/50Hz AC voltationem sinusoidei resistunt pro 1 momento inter instrumenti wiring et testa. |
Insulation | Inter instrumentum wiring et testam ≥10MΩ. |
Structure | Duplex velit, cum velit vibration-proof sheath. |
Tutus praecepta | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, pollutio gradus: II. |
3.3.Instrumentum praecisionem (exclusis sensorem currentem)
Respective sequentia data (in fundamentis basium conditionibus et sensoriis hodiernis idealibus, perfecte linearibus, nulla periodo trabea).
Mensuratio | Range | Propono resolutio | Maxime errorem rhoncus referat |
Frequentia | 40Hz~ 70Hz | 0.01Hz | ±(0.03)Hz |
Verum RMS tempus-ad-medium voltage | 1.0V~ 1000V | Min resolutio 0.1V | ±(0.5%+5dgt) |
Verum RMS tempus-ad tempus voltage | 1.0V~ 2000V | Min resolutio 0.1V | ±(0.5%+5dgt) |
DC voltage | 1.0V~ 1000V | Min resolutio 0.1V | ±(1.0%+5dgt) |
Verum RMS current | 10mA~ 10A | Min resolutio 1mA | ±(0.5%+5dgt) |
Apicem of tempus-ut-medium voltage | 1.0V~ 1414V | Min resolutio 0.1V | ±(1.0%+5dgt) |
Apicem of tempus-ut-phase voltage | 1.0V~ 2828V | Min resolutio 0.1V | ±(1.0%+5dgt) |
Current apicem | 10mA~ 10A | Min resolutio 1mA | ±(1.0%+5dgt) |
Apicem factor | 1.00~ 3.99 | 0.01 | ±(1%+2dgt) |
4.00~ 9.99 | 0.01 | ±(5%+2dgt) | |
Active virtus | 0.000W~ 9.999kW | Min resolutio 0.001W | ±(1%+3dgt) Cosφ≥0.8 |
±(1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Reactivum potentiae, inductivum vel capacitivum | 0.000VAR~ 9.999kVAR | Min resolutio 0.001VAR | ±(1%+3dgt) Sinφ≥0.5 |
±(1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Apparens potentia | 0.000VA~ 9.999kVA | Min resolutio 0.001VA | ±(1%+3dgt) |
Potentia factor | -1.000~ 1.000 | 0.001 | ±(1.5%+3dgt) Cosφ≥0.5 |
±(1.5%+10dgt) 0.2≤Cosφ<0.5 | |||
Active navitas | 0.000Wh~ 9999.9MWH | Min resolutio 0.001Wh | ±(1%+3dgt) Cosφ≥0.8 |
±(1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Reactivum industria, inductivum vel capacitivum | 0.000VARh~ 9999.9MVARh | Min resolutio 0.001VARh | ±(1%+3dgt) Sinφ≥0.5 |
±(1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Papparent navitas | 0.000VAh~ 9999.9MVAh | Min resolutio 0.001VAh | ±(1%+3dgt) |
Phase angulus | -179°~ 180° | 1° | ±(2°) |
Tanφ (VA≥50VA) | -32.76~ 32.76 | Min resolutio 0.001 | φ:±(1°) |
Subcinctus tempus elementum potentiae (DPF) | -1.000~ 1.000 | 0.001 | φ:±(1°) |
Ratio harmonica (ordine 1 ad 50)(Vrms>50V) | 0.0%~ 99.9% | 0.1% | ±(1%+5dgt) |
Angulus harmonicus (Vrms>50V) | -179°~ 180° | 1° | ± (3°) harmonica ordinis 1 ad 25 |
± (10°) harmonica ordinis 26 ad 50 | |||
Summa harmonica ratio (THD vel THD-F) ≤50 | 0.0%~ 99.9% | 0.1% | ±(1%+5dgt) |
Distortio factor (DF vel THD-R) ≤50 | 0.0%~ 99.9% | 0.1% | ±(1%+10dgt) |
Transformer K factor | 1.00~ 99.99 | 0.01 | ±(5%) |
III temporibus unbalance | 0.0%~ 100% | 0.1% | ±(1%) |
3.4.Current sensorem character
Typus de current sensorem | Verum RMS current | Max error veri RMS current | Max errorem tempus angulus φ |
008B fibulae current | 10mA~ 99mA | ±(1%+3dgt) | ±(1.5°), Arms≥20mA |
100mA~ 10.0A | ±(1%+3dgt) | ±(1°) | |
040Fibulae B current | 0.10A~ 0.99A | ±(1%+3dgt) | ±(1.5°) |
1.00A~100A | ±(1%+3dgt) | ±(1°) | |
068Fibulae B current | 1.0A ~9.9A | ±(2%+3dgt) | ±(3°) |
10.0A~1000A | ±(2%+3dgt) | ±(2°) | |
300Fvena Fibulae | 10A~99A | ±(1%+3dgt) | ±(3°) |
100A~3000A | ±(1%+3dgt) | ±(2°) |
Nota: fibulae venae et instrumenta ad respondentem coniungi debent, contrarium inseri non possunt.
4.1.Configuratione Latin
Nec. | Designatio | quantitas |
1 | Instrumentum castrorum. | 1 |
2 | Instrumentum sacculi. | 1 |
3 | Current sensoriis. | 12 (3 species); |
4 | Probatio fila. | 5 (flavae, viridis, rubrae, caeruleae, nigrae); |
5 | Crocodilus tondet. | 5 |
6 | Probae probe. | 5 |
7 | Dedicata potestati nibh. | 1 |
8 | funis USB date. | 1 |
9 | Software CD. | 1 |
10 | Lithium altilium sarcina. | I (instructum in instrumento) |
11 | 2GB memoriae. | 1 (Plug in instrumento) |
12 | Manuale, warantia chartae, certificatio. | 1 |
4.2.Pondus
Nec. | Designatio | Pondus |
1 | Instrumentum castrorum. | 1.6Kg (cum altilium). |
2 | 008B parva fibulae acuta vena. | 170g*4. |
3 | 040B circumfibulae vena. | 185g*4 |
4 | 068B circumfibulae vena. | 530g*4 |
5 | 300FFlexibile coil venaFibulae(with integrator). | 330g*4 |
6 | iora proba et potentia nibh. | 900g. |