GDPQ-300E Power Quality Analyser
GDPQ-300E Potentia Qualitas Analyser est fabrica portatilis probandi et analysis potentiae systematis operandi qualitatis.Is monitores et notitias colligit in longo cursu temporis, etiam analysin harmonicam ac potentiam qualitatis analysi praebet.Interea programmata analysi analysi aptat, qua mensura notitiae ad PC imponendae possunt.
●ARM et DSP, 16M byte memoria.
●Tange screen, more easy and convenient.
●Data mensurae et salutaris, possunt ad PC impositi.
●OMNIBUS structura, rationabili consilio et operatione certa.
●Phasellus luctus commodo facilisis.
●Detailed analysis mensurae datae per potentiam qualitatis analysi in PC programmatis.
Metrum detectio munera
No | Items | Descriptio |
1 | Voltage/Current/Frequency | Potest metimur tribus-phase voltage, nulla linea voltage, tres phase current, nulla linea current, frequentia. Praetendere potest RMS, apicem valorem, fluctus / apicem rationem, fluctus forma, trend chartis etc. |
2 | Harmonic fluctus mensurament | Potest metimur fundamental unda voltage ac vena ac2~50 times harmonicsfluctus.Mensurae eventus comprehendunt efficientiam harmonicam, contentum harmonicum, contentum harmonicum ac totam corruptelam harmonicam (THD).Histograms and trends charts, etc. |
3 | Interharmonica mensura | Metiri potest 0.1 ~ 19.9 temporibus interharmonica intentionis et vena.Mensuratio eventus comprehendit elementa interharmonica et valores effectivos subseti, rate contentorum interharmonica etc. proponere potest histogrammata, chartis tenoris, etc. |
4 | Virtus mensura | Potest metimur tribus-tempus quattuor filum / tres tempus tres-filum apparent potentia (electrica industria), potentia activa (electrica industria), Reactivum potentiae (electrica industria), potentia factor etc., potest ostenderetrend charts; non metimur postulatio of 1, 5, 10, 15, 30 60 minuta. |
5 | Tria tempus unbalance mensura | potestmetire three-phase four-filum / three-phase three-filum electrical system voltage and current positive sequence component, negative sequence component, zero sequence component, negative sequence Gradus iniquitates: nulla series inaequalitatis gradus;Phase angulus trium Phase intentionis et currentis ,vector, trend chartis. |
6 | Flicker | 1 minute flammis, 10 minutis brevibus vibrat, 2 horae longam vibrat measurement |
7 | Intentione tumorem / Dip / Interruptionem | Detegit etacta voltage intumescit, opinor, et interruptiones praesagia. |
8 | Surge current | Detegit ac robora surge eventorum |
9 | Harmonica potestas | Potest deprehendere 2 ~ 30 temporibus harmonica potestas, histogrammum ostendere potest, trend .charts, etc. |
10 | Virtus fluctus | Cmoderatio celeris mutationis potentiae (activa, reactiva, apparentis potentiae) secundum tempus statutum (1~5 minuta) |
11 | Vagi | Cet deprehendere voltage vagorum diutius quam XX microseconds |
8 | Cras record | Notare potest stabilis status potentiae qualitas parametri diu, incluso intentione / currenti / frequentiae, harmonicae, potentiae, trium temporum iniquitate, fluctuatio, vibratio, et intervallum recordatio ab 3 secundis ad 30 minuta componi posse. |
9 | Digital oscilloscope | Visum voltage / current signo fluctus formam |
Quisque accurate index ad deprehendendum munera
Item | range metimur | Accurate metimur | Animadverte |
Voltage / current /frequency | Three tempus voltage: 1000V (valorem efficacem) Zero linea intentione: 70V (valorem efficacem) Three tempus current: 6000A (valorem efficacem, 1000A sensorem ad libitum current) Zero linea current: 25A (valorem efficacem) Fpostulatio: 40-70Hz | Voltage:0.1%rdg±0.05%fs Current: 0.2% rdg±0.05%fs Frequency: Lectio±0.01Hz | Hante |
Harmonic mensura fluctus | Voltage harmonic: THD+Fundamental unda+ 2-50 tempore harmonicae undae. Current harmonica: THD +Fundamental unda+ 2-50 tempore harmonicae undae. | Voltage harmonic wave: Uh≥1%UN±5%Uh. Uh<1%UN±0.05%UN Vena harmonica unda: Ih≥3%IN±5%Ih. Ih<3%IN±0.15%IN | |
Inter harmonicfluctusmetimur | Voltage harmonic: 0.1~ 19.9 timesInter harmonicfluctus . Current harmonica: 0.1 ~ 19.9 temporibusInter harmonicfluctus | VoltageInter harmonicfluctus: Uih≥1%UN.5% Uih. Uih<1%UN.0.05%UN. CurrentInter harmonicfluctus: Iih≥3%IN.5%Iih. Iih<3%IN.0.15%IN | |
Power / Energia electrica | Apotentia activa: 700kVA Rpotentia activa: 700kVAR Potentia factor: 0.00~1.00 Avirtus activae industria: 10000kWh Apparent power navitas: 10000kVAh Rpotentia activa industria: 10000kVARh Average potentia factor: 0.00-1.00 | Active: Lectio±0.5% Apparent: Lectio±0.5% Reactivum: Lectio±0.5% Power factor: Lectio±0.005 | |
Three tempus unbalance | Fundamental intentione: 1000V (valorem efficacem) Fundamental current: 6000A (valorem efficacem) Ffrequentia undamentalis: 40-70Hz Phase angulus: 0-360degree Unbalance: 0.0%-100% | Voltage: 0.1% rdg±0.05%fs Current: 0.2% rdg±0.05%fs Frequency: Lectio±0.01Hz Phase angulus: Lectio±0.3degree Voltage unbalance: Lectio±0.2% Current unbalance: Lectio±0.2% | Hic, frequentia Phase intentionis utimur sicut mensura totalis frequentiae |
Voltage Flicker | 1 minuta flammis, brevi flammis, diu flammis | I minutis flammis:±5.5% X minuta brevis flammis:±5% II horas longum tempus flammis:≤±5% | |
Voltage intumescere, intinge et interrumpere | Monitor et record unus-phase/multi-phase intentione distenta, voltage intinge et potentia temporalis-off | Medium unda RMS, initium temporis, durationis, finis temporis error ± 10ms | Ad XL res records |
Surge Current | Monitor et recordum unius tempus / multi tempus impetus flumina | dimidia pars rms pretii, initium temporis, durationis, finis temporis error ± 10ms | Desine metiendis cum capto eventus |
Harmonic unda potentiae | Totalis potentiae harmonicae temporibus: 1 ~ 30th Harmonica totalis potentia activa;ΣP Harmonica totalis potentia reciprocus:ΣQ Positiva harmonica totalis potentia activa: +ΣP Negative harmonica totalis potentia activa: -ΣP Positiva harmonica totalis potentia reciprocus: +ΣQ Negative harmonica totalis potentia reciprocus: -ΣQ | Vis harmonica lectio: ± 0.5% | |
Virtus fluctus | Potest deprehendere 1, 3, 5, minuta longitudinis potentiae activae, reactivae, mediae undae apparentis valoris, memoria potentiae mutationis trend . | Lectio dimidia unda potentia: ± 0.5% | |
Transiens | Voltage vagorum secundum nominis valorem plus quam CXX% | 1.tet minimum tempus mensurabile certe plus quam XX microseconds 2.probabilitas res captis 98.7% | XX certe potest condi in una mensura |
Monitoring recordum | Record parametri includuntur intentione, currente, frequentia, intentione/fluctu harmonicae currente (totalis harmonicae + 1-25 temporum harmonicae), three-phase unbalance;activa/reactiva/apparens potentia, factor potentiae;fluctuatio / flammis | Data repono intervallum: 3s ~ 30min Intervallum est 3s, et tota vigilantia tempus est 16h; Intervallum est 30min, et tota vigilantia tempus est 960h. | |
Doscilloscope igital | Three phase voltage, tres periodi current, nulla linea voltage ac nulla linea vena instantis aquae forma | Maximilianus.sampling frequency: 200kHz Min.sampling frequency: 100Hz |
●Signum intentionis initus loop:
Accessus directus, initus impedimentum: 1MΩ, 20pF
Mensura range: voltage valentia 1000V
Virtus consummatio: minus quam 0.5VA / phase
●Current initus loop:
Accessum indirectum
Mensurae ambitus: Current valorem efficax 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (selectae sensori currenti respondente)
Virtus consummatio: Minus quam 0.5VA/phase
●Metire signum frequentiae range: 40Hz-70Hz
●Propono velum: 5.7 inch 640 *480 color LCD cum screen tactus
●Memoria repono: 128M byte FLASH
●Extra portum repono: USB (obturaculum in USB orbis)
●Copia potentiae operandi: Rechargeable li-altilium, 5-6hours operantes tempus plenum crimen
●Potentia copia: AC100-240V/DC 16.8V-1A potentia adaptor/discus
Tester | 1 set |
5A Fibulae Current | III pieces |
Tentatio test filum | Pars I |
Virtus nibh | Pars I |
Conversus filum | Pars I |
QC pass | 1 copy |
User scriptor Manual | 1 copy |
Factory test fama | 1 copy |
Sarcina album | 1 copy |