GDYB-S20 Tres Phase Energy Meter Test System
GDYB series Tres Equales Potentiales Multi-munus Electric Energy Meter Test System bene explicatur tertia generatio electronic programmabilis tribus phase electrici energiae metrorum multifunctionalis ratio examinis secundum recentissima signa et normas nationales.Adoptat insulatas 0.01% alta praecisione 1:1 technologiam commutator current, ut experimentum voltage interioris connexum ad tres phases metros shunt.Apta est ad probandas varias tres periodos energiam electricam metri 0.2% et infra (includit potentiam reactivum metri sinusoidalis).Habet speciem bonam, munera perfecta et praestantem effectum.
GB/T 1150-2001 Instrumentum probatio electrica metrorum energiae (neq IEC 60736)
JJG 307-2006 Electromechanical Meters for Mensuring Alternating-current Electrical Energy
JJG 596-1999 Electrical Energy Meters with Electronics
JJG 597-2005 Verificationis Equipment for AC Electrical Energy Meters
DL/T 614-1997
DL/T 614-2007 Multifunctioni electricitatis armorum metrorum (AC)
Environmental condition
Temperatus environmental operans: 23℃±2℃.
Operans humiditatem environmental: 45%~75%.
Potentia copia
Unius periodi: AC220V±33V.Frequentia: 50±2.5Hz
Type No.: GDYB-S20 Three Phase Electric Energy Meter Test System.
Ratio accurationis: 0.05%.0.1%.
Vexillum metri accurationis: 0.05% Tribus phase multi-functionalis metri vexillum.
Voltage & Current metiendi range:
Output voltage step: 57.7V/100V/220V/380V.
Output current step: 0.005A, 0.025A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A.
Minimum Output current: 1mA.accurate: ≤5%.
Facultatem output onus (XX metris)
Voltage output: 800VA.
Current output: 2500VA.
Voltage & current temperatio
Populus Novifacta range: (0%~ 120%) x range metientes.
Elegantiae subtilitatis: 10%, 1%, 0.1%, 0.01%.
Tempus temperatio:
Adjustable range: 0°~ 360°.
Elegantiae elegantiae: 10°, 1°, 0.1°, 0.01°.
Frequentia temperatio:
Product range: 45Hz~65Hz.
Elegantiae elegantiae: 1Hz, 0.1Hz, 0.01Hz.
Virtus stabilitatis output: ≤0.05%/120S.
Output voltage & current corruptelam:
Voltage: ≤0.5%.
Current: ≤0.5%.
Harmonic occasus:
Harmonicus numerus: 2~21 temporibus.
Contentum harmonicum: current 2~21 times ≤40% (respectus ad undam fundamentalem).
intentione 2~21 temporibus ≤40% (respectu ad undam fundamentalem).
Harmonica periodus: 0°~359.99°.
Instrumentum vigilantia:
Latin meter ostentationem accurationis: Voltage: 0.01%.
Current: 0.01%.
Virtus: 0.01%.
Phase: 0.01.
Frequentia: 0.01.
Insulae I: I parametri vena TRANSFIGURATOR:
Sagaciter: 0.01%.
Output power: 60VA.
Current mensurae mensurae: 1mA~ 120A (1:1).
Praecipua perficientur index
a) Cura: 0.01% (COS∮=0.5C…1…0.5L).
b) Ratum frequentiam: 50Hz/60Hz±5%.
c) Praesens primarium: 3×0.001-120A.
d) Secundae currentis: 3×0.001-120A.
e) output onus (singulis temporibus);
0.5W (output range: 0.001-1A).
0.7V valore currenti divisa (output range: 1-120A).
f) Output onus voltage: Max.0.5V (output current Max. 120A).
Vena transformator dimensio: 265 x 200 x 240 mm (L x W x H).
Pondus: 12kg.
Dimensio:
Imperium source: 610 x 800 x 1920mm (L x W x H).
Meter eculei: 2350 x 750 x 1850mm (L x W x H).