Products

  • GDQH-31W Portable SF6 Gas Recovery Device

    GDQH-31W Portable SF6 Gas Recuperatio Fabrica

    GDQH-31W Portable SF6 Gas Recuperatio Fabrica (MINI) adhibetur in fabricandis plantis SF6 gasi insulatis instrumenti electrici et operationis & inquisitionis scientificae ad implendum apparatum electricam cum SF6 gas et recipiendum SF6 gas ab adhibitis electricis adhibitis vel probatis.

    eodem tempore purgatur et comprimitur et in piscina reconditur.Apta anuli retis distributio retis infra 50kV.

      

     

     

  • Partial Discharge Test System GIT series

    Partialis fungi Test Ratio GIT series

    GIT series late usus est pro alta intentione, magna capacitate GIS instrumenti potentiae insulatae sustinendi voltage test, partialis missionis experimenti et GIS transformatoris accurationis test, GIS substationi apta, GIS instrumenti potentiae fabrica, pelvis genus electricum insulator opificem.

     

     

     

     

     

  • GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test

    GDSL-A Automatic III-phase Primae Current Iniectio Test Set cum Temperature Test

    GDSL-A Series 3-phase Primary Current Injection Test Set cum Temperature Test est specimen instrumentum ad probandum summus currentis machinam in potentia et industria electrici, adhibita in plantis potentiae, stationum distributionis potentiae, fabricandis electricis et Institutis inquisitionis, cum lineamentis modicus, leve pondus, facilis usus et sustentatio.

     

     

     

     

  • GDCY Impulse Voltage Test System (100kV-7200kV)

    GDCY Impetus Voltage Test System (100kV-7200kV)

    Impulsio Voltage Test System maxime adhibetur ad plenam undam fulguris impulsum voltage test perficiendam, impulsus impulsus test et mutandi impetus test in HV apparatus sicut transformatores, impetus comprehensor, insulatores, bushings, capacitores, et virgas.Vexillum generare potest fluctus fulminis, fluctus mutans, undam secans amplis intentione et industria.

     

     

  • Partial Discharge Test System GDYT series

    Partialis fungi Test seriei Ratio GDYT

    In electricis fabricandis, operationibus potentiae Dicasteriis, investigationibus Institutis ac Universitatibus pervestigandis, usus est.

     

     

  • GDBT-1000kVA Transformer Test Bench

    GDBT-1000kVA Transformer Test Bench

     

     GDBT Transformer Expertus Systema perducere potest omnes exercitationes probationes pro transformatoribus, incluso No-onere et onere test, tentatio intentionis inducta, potentiae frequentiae test voltage, partialis missio test, DC resistentiae test, ratio test, temperatura ortu test etc.

     

     

     

  • PD free Variable Frequency Test System

    PD gratis variabilis Frequency Test System

    GDYT-350kVA/70kV PD gratis Resonant Testis Ratio componitur ex PD libera frequentiae variabilium potentiarum copia, HV arca mensurandi, excitatio transformator, solitudo transformator, reactor resonans et dividens voltage capacitiva.

     

     

     

     

     

  • GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ)

    GD3126A (GD3126B) Insulation Resistentia Tester 5kV/10TΩ (10kV/20TΩ)

    Apta est ad mensurationem resistentiae insulationis (IR), absorptionis rationum (DAR), index polarizationis (PI), lacus currentis (Ix) et capacitatis effusio (Cx) omnium generum altae intentionis instrumentorum, inclusorum switchgear, transformatorum; reactores, capacitores, motores, generatores et rudentes, etc.

  • Lead Acid Battery Regenerator

    Plumbum acidum Pugna Regenerator

    Cogitatus peculiaris est machina ad activum pilae valvae ordinatae acidum cum altilium intentione 2V, 6V, vel 12V et capacitatis retrorsum ob crystallizationem laminae electrae sulfidis.

  • GDDO-20C AC/DC Electric Meter Calibration Device

    GDDO-20C AC/DC Electric Meter Calibration Device

    GDDO-20C AC/DC Meter Electric Calibration Fabrica usus est ad deprehendendum fundamentalem errorem variarum potentiarum frequentia instrumenta electrica in systematis potentiae, inter voltmeter, ammeter, wattmeter, ohmmeter, una periodus & tres gradus AC metrorum industria (libitum) et error fundamentalis dc volt-metriis et ammetris.

  • GDYN-901 Kinematic viscosity tester

    GDYN-901 Viscositas testor Kinematicus

    GDYN901 idoneum est viscositatem kinematicam liquidi petrolei producti determinare.Hoc apparatus munus habet timoris motus exempli specimen et ultimum exitum viscositatis kinematicae computare potest.

  • Onsite AC power supply

    Legamen ac potentia copia

    GDUP-1000 versatile est portatile purum sine undo in-site AC potentia experimentorum copia.Etiam nota ut on-site AC et DC vim examinis copiam, AC et DC vim subitis copiam, agri experimentum potentia copia, potentia probata mobilis copia.

123456Next >>> Page 1 / 15

Epistulam tuam nobis mitte;

Epistulam tuam hic scribe et mitte nobis