GDYZ-302W Metal Oxide Arrester (MOA) Tester
1) Lacus current, AC current
Range | Resolution | Sagacitas |
0.000mA~1mA | 1uA | ±1%rdg±8dgt |
1.00mA~10.00mA | 0.01mA | |
10.0mA~100.0mA | 0.1mA | |
100mA~300mA | 1mA |
2) Vena harmonica summus ordo (fluctus fundamentalis vena, tertia vena harmonica)
Minimum fundamentalis fluctus input current | Super III% cuiusque range |
Sagacitas | 1%rdg±8dgt (± AC accurate current) |
Officium | Cum probatio plenam vim zinci oxydi comprehensoris, iudicari potest an oxydorum zinci comprehensor deminutus sit, et etiam adhiberi potest ut fibulae ultra-praecisionis in metro currenti lacus. |
Potentia copia | Exercitus: DC 7.4V 2000mAh rechargeable eu altilium, pila est de 8.4V plene comminataDetector: DC 7.4V 2600mAh rechargeable lithium altilium, pugna est de 8.4V plene comminatus |
Testis modus | Fibulae in CT |
Mensurae range | AC 0.000mA~300mA (valorem verum) |
Maximilianus.resolutio | 1μA |
Mensuratio accurate | ±1% rdg±8dgt (23±5℃, infra 80% RH) |
Wireless communicationis | 433MHz communicationis wireless |
Wireless tradenda procul | 30m |
Propono modus | 3.5-inch color screen;propono area: 71mm×53mm |
Instrumentum magnitudine | Host: 195mm×100mm×45mm;Detector: 208mm×131mm×90mm |
Instrumentum pondus | Host: de 400g;detector: about 1220g;Summa: de 7000g (including insulating virgas et fortia) |
Fibulae magnitudine | φ40mm |
Sampling rate | 2 times/s * |
Date repono | 200 Circuli "PRAETEMPTO" symbolum in repositione indicat. |
Data hold | In modo examinis, premere clavem tenere datam ac reponere notitias, "PRAETEMPTO" symbolum monstratur, et tunc clavem clavem ad inrita premunt. |
Reprehendo notitia | "Legere" symbolum indicat notitia condita condita posse sursum et deorsum flipped. |
Superfluum | "OL" ostendit exundare experimentum patens. |
Nullum signum | Cum receptor hospitis signum detectoris non recipit, status praesentis detectoris ostendi non potest. |
Auto off | Instrumentum automatice averte post 10min ut nisi altilium. |
Pugna voltage | Cum altilium voltage infra 7.8V est, tempus ostendit pilae mutare. |
Linea voltage | 35kV et infra |
Mauris caliditas et humiditas | -20℃ ~40℃; infra80% Rh |
Repono | -20℃ ~60℃;infra70% Rh |
impedimentum | No 433MHz frequency signum intercessionis |
Insulating virga magnitudine | 4-sectio dis-button virgae insulantis telescopicae (status extensus 5m, status clausus 1.5m, diametri exterioris φ44mm) |
Nulla vis | Una insulating virga AC110kV/rms, testa HV *detectorinter nucleum ferreum: AC1000V/rms |