GD3128 Series Insulation Resistentia Tester
GD3128 series Insulation Resistentia Tester habet perfectam probationem functionis variarum parametri insulationis resistentiae et excellentiae anti-incessionis facultatis, quae adhiberi potest ad probandum resistentiam insulationis magnae capacitatis altae voltage electrici instrumenti et lineas transmissionis in valido ambitu inductivo sicut substatio.Instrumentum verum colorem tactum velum adhibet, omnia probata data et pugnae potentiae in eodem velo aspectu monstrantur, et compositio nodi switch et clavis operationem simplicissimam facit.Usor operandi modum meminisse non indiget.Preme "auxilium" in velo ad modum operandi pop sursum, quae efficaciter utentem dirigit ad instrumentum operandum.Instrumentum munus habet emissionis ieiunii, quae intentione rei probatae statim potest fungi sine circuitione adiectis emissionibus.Monitor in intentione instrumenti potest automatice monitorem vivam intentionem rei probatae.Si intentione 36V excedit, probatio ipso facto prohibetur, quae instrumentum et operatorium efficaciter tueri potest.
Instrumentum magnam facultatem rechargeable lithium altilium sarcinas adoptat.Expertus timer instrumenti statim commemorat tempus testium ac proventus probationis cum tempore et tempore reponit.Tegumentum tactus facile potest accessere notitiae historicae memoriae.Interface USB omnino remotus potest fiducialiter notitias ad PC plicare.Instrumentum cum linea testarum duplicibus velit et strato protegente instructum est, et talea alta intentione aptatur ad repositorium alligatoris clip et hamum, quod variis locis examinis accommodare potest.Instrumentum solidam duplicatam testam structuram adhibet, et gradus tutelae arcae exterioris IP65 est, quae incursus umoris et pulveris in translatione et repositione impedire potest, et instrumentum a collisione efficaciter defendat.
Series GD3128 late patet, altam resolutionem, opportunam operationem, robur et firmitatem, accurationem et constantiam, stabilem operationem et validam facultatem anti-impedimenti.Instrumentum velit resistentiae test (IR);index polarizationis test (PL);effusio ratio test (DAR);aggerem test(amp);colum test (FR, 10S, 20S, 30S, 40S quattuor optiones);voltage test (V);capacitas test (uF);probatus monetae (nA) et alia munera.Instrumentum aptum est resistentiae insulationi experimentum instrumenti electrici, lineae transmissionis et aliorum magnorum instrumentorum sub ambitu magnae capacitatis, altae intentionis et inductionis fortis.Communiter usus est et necessarium instrumentum pro potentia electrica, telecommunicationes, meteorologia, locus computatralis, campus oleum, institutionem electromechanicam et sustentationem, et potestas copia Dicasteriorum inceptis industrialibus et fodiendi.
●Maxime brevis-circuitus currentis est 7mA.
●Insulatio resistentiae test (IR), index polarizationis test (PI), effusio ratio test (DAR).
●Aggerem test modus (RAMP), filter test mode (FR), capacitance test (uF)
●Munus intentionis monitoris, automatice monens intentionem rei probatae obicitur.
●Munus test timer, automatice test tempus.
●Munus automaticum missionem, sponte et celeriter crimen rei emittere post experimentum, sine circuitione externa missione.
●Automatic munus shutdown.
●Magnae tactus colore velamento.
●Testa duplex structura, solida et durabilis, gradus tutelae IP65.
●Summus capacitas rechargeable lithium altilium pack.
●Repono munus, sponte 1000 circulos testium realis-vicis notitias condere cum test date et tempore ac test sincere.
●Munus onerati, cum USB interface instructum, notae recordationis ad computatorium statisticae analyseos notitiae statisticae impositi possunt.
Product Model | Rated Voltage | Nulla Resistentia dolor | Brevis Circuitu Current |
GD3128A | 250V,500V,1kV,2.5kV,5kV | 0.50MΩ~10.0TΩ | ≥7mA |
GD3128B | 250V,500V,1kV,2.5kV,5kV,10kV | 0.50MΩ~20.0TΩ | ≥7mA |
GD3128C | 250V,500V,1kV,2.5kV,5kV,10kV,15kV | 0.50MΩ~30.0TΩ | ≥7mA |
Nulla Resistentia dolor et accuratio
Rated Voltage | Nulla Repugnantia Ira | Sagacitas | Animadverte |
250V | 0.50MΩ~50.0GΩ | ±5%rdg±3dgt |
|
50.0GΩ~500GΩ | ±20%rdg±3dgt |
| |
500V | 1.00MΩ~100GΩ | ±5%rdg±3dgt |
|
100GΩ~1.00TΩ | ±20%rdg±3dgt |
| |
1000V | 1.00MΩ~200GΩ | ±5%rdg±3dgt |
|
200GΩ~2.00TΩ | ±20%rdg±3dgt |
| |
2500V | 1.00MΩ~500GΩ | ±5%rdg±3dgt |
|
500GΩ~3.00TΩ | ±20%rdg±3dgt |
| |
5000V | 1.00MΩ~1.00TΩ | ±5%rdg±3dgt |
|
1.00TΩ~10.0TΩ | ±20%rdg±3dgt |
| |
10KV | 1.00MΩ~2.00TΩ | ±5%rdg±3dgt |
|
2.00TΩ~20.0TΩ | ±20%rdg±3dgt |
| |
15KV | 1.00MΩ~3.00TΩ | ±5%rdg±3dgt |
|
3.00TΩ~30.0TΩ | ±20%rdg±3dgt |
1 TΩ (Tera olim)=1000GΩ=1012Ω
1 GΩ (Giga olim)=1000MΩ=109Ω
1 MΩ (Mega olim)=1000KΩ=106Ω
Officium | Resistentia insulationis mensurae (IR);index mensurae polarizationis (PL);effusio ratio (DAR);modus test aggere (ramp);filterofficium(10S, 20S, 30S, 40S);voltage mensurae (V);capacitascessationesmeasurement(uF);current measurement(nA) |
Potestas Supple | Lithium rechargeable altilium 6.2Ah |
Rated Voltage | GD3128A: 250V, 500V, 1kV, 2.5kV, 5kV GD3128B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV GD3128C: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV, 15kV |
Output intentione Sagaciter | (5%~10%) ±10V |
Nulla Repugnantia Test dolor | GD3128: 0.50MΩ~10.0TΩ GD3128B: 0.50MΩ~20.0TΩ GD3128C: 0.50MΩ~30.0TΩ |
Output Short Circuit Current | ≥7mA |
Index polarisation Test | Ita |
Rationis testi effusio | Ita |
Aggerem Test Modus | Test per gradus 10% de intentione praesentis usque ad praesentem intentionem. |
Filter Test Modus | 10S, 20S, 30S, 40S quattuor excerpta. |
Voltage Test | Range: AC/DC: 0V~1000V; Cura: ±5%rdg±3V |
Facultas Test | Range: 10nF~25uF; Cura: ±10%rdg±10nF |
Current Test | Range: 0.01nA~7mA; Cura: ±5%rdg±0.5nA |
Voltage Monitor | Monitor voltage of thetested objectum, et monitor status missionis post test, prohibitus est experiri cum intentione 36V excedunt, instrumentum et operator protegunt. |
Test Timer | Automatic record test tempus, timingrange: 0s~9999s |
Repono Function | Automatice reponunt data test cum date et tempore, summa 1000 circulorum |
Index Function | Upload condita data ad computatrum per USB remulco communicationis. |
Pugna Power Display | Cum altilium potentia ostentationem, cum altilium intentione humilis admonebitcrimenin altilium. |
Lorem Shutdown | Post XV minuta surgamus claudet statim sine ulla operatione. |
Dimension | 280mm×260mm×160mm |
Pondus | 4900g (includere altilium) |
Test Wires | Color rubeus summus voltage test filum 1pc (cuma alligator clip et hamo), color viridis test filum 1pc, color test filum nigrum 1pc |
Praesidium Level | Claude causam IP65, causam aperi IP40 |
Situs laboris | -20℃~50℃; 80% rh |
Store Environment | -25℃~65; 80% rh |
Nulla Resistentia | 50MΩ(1000V) (inter experimentum circuitu et concha) |
sustinere intentione | AC 3kV50Hz 1min(inter experimentum circuitu et concha) |
salus | IEC61010-1, IEC61326-1 |