-
GDCR1800A Wireless High Voltage Detector
GDCR1800 series wireless high voltage tester (with voltage and current indication) is specially designed and manufactured for high voltage transmission line inspection, high voltage transmission line to ground voltage, induced voltage test and current test. This instrument can test the high-voltage to ground at the same time as the alarm of the power check.
GDCR1800 series wireless high voltage electroscopes have a voltage level of 0.1kV ~ 220kV, which completely covers the power and ground voltage test of each voltage level (3kV, 6.3kV, 10kV, 35kV, 66kV, 110kV, 220kV). which is safe, reliable and saves time. It is an indispensable tool for power transmission line maintenance. During the inspection and maintenance of the transmission line, even if the line has been disconnected, due to the capacitive effect, there may still be very high voltage through induction, which seriously threatens the safety of the operator and the operating process. Make sure the voltage has dropped to a safe and operational voltage level.
-
GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ)
It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc.
-
GDCR3000B Digital Earth Resistance Tester
GDCR3000B Earth Resistance/Soil Resistivity Tester is special designed for measuring earth resistance, soil resistivity, earth voltage and AC voltage. The latest digital and micro processing technology is adopted, to measure earth resistance by 4-pole, 3-pole or 2-pole.
-
GD2000D Insulation Resistance Tester
GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined.
-
GDHX-1820 Non-contact High Voltage Detector
GDHX-1820 non-contact high voltage detector is specially designed and manufactured for high-voltage transmission line inspection. The product is used for on-site high-voltage line inspection, identification of high-voltage system voltage level, inspection of high-voltage line faults, repair of neon lights, high-pressure sodium lamps, inspection of induced voltage, and inspection of residual high voltage or induced voltage.
-
GDDT-10U Digital Grounding Down Lead Earth Continuity Tester
GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment.
-
GD2000H 10kV Insulation Resistance Tester
This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components.
-
GDHX-8300F Wireless Phase Detector
GDHX-8300F Wireless Phase Detector is mainly used for phase sequence identification and labeling of power transmission and distribution lines.
Its working principle is: the phased base station regularly collects the phase signal of a certain area line as a standard signal and uploads it to the main station server. During measurement, the sensor collects the measured line signal and sends it to the handheld device. The handheld device applies to the server for the data of the phasing base station at the same time. By comparing the two phase data, the true phase of the measured line can be calculated.
The complete set of equipment mainly consists of the main station server, phasing station, handheld machine, sensors and accessories.
-
GDF-3000 DC System Earth Fault Detector
In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault.
-
GD3127 Series High Voltage Insulation Resistance Tester
GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc.
-
GDHX-9500B High Accuracy Phase Detector for Electrical Systems
GDHX-9500B Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.
-
GDCR3000 Digital Earth Resistance Tester
It is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement.