In mid-December, Jiangsu customers purchased a batch of oil chemical analysis equipment from our company.


After comparing many manufacturers, the customer evaluated the company’s strength, and finally decided to sign a purchase contract with our company. As soon as the contract was signed, the production department of HV HIPOT quickly coordinated and worked overtime to deliver high-quality goods and deliver them to customers. The equipment purchased by the customer this time includes: GDC-9560B power system insulation oil gas chromatograph analyzer. GD6100 transformer oil tan delta tester, GDSZ-402 automatic oil acid value tester, GDW-106 oil dew point tester, GDOT- 80A insulating oil tester and other equipment.
The special oil chromatographic analyzer for electric power system is a computer-controlled multi-purpose high-performance series of special oil chromatographic analyzer for electric power system. The GDC-9560B special oil chromatograph for electric power system has a fully automatic control system. The attenuation and zero adjustment of the measuring circuit are all controlled by the buttons, and the stability and reliability are high. It is widely used in electric power, petroleum, chemical industry, metallurgy, environmental protection, food, medicine, health and various scientific research fields.

GDC-9560B power system insulation oil gas chromatograph analyzer
Features
Convenient operation: Chinese WINDOWS operating platform, full Chinese window interface, real-time operation prompts and online help, which are convenient for users to learn and use.
Real-time: real-time data acquisition under the real WINDOWS environment, dual-channel simultaneous sampling, real-time display of chromatographic peak retention time.
High precision: 24-bit high precision A/D plug-in card, input range: -1v~+1v.  
Reproducibility: 0.006%.  
Open data management: save complete related equipment information and analysis result data information, convenient to add, modify, delete, and read and retrieve at will. The open data format is suitable for multi-user data sharing to facilitate the access of other database management software and the retrieval requirements of management departments.
Automatic fault diagnosis: after the analysis, it will automatically indicate that it exceeds the limit, provide three-ratio diagnosis that meets the national standard, TD diagram, component concentration diagram and other fault diagnosis methods.  
Easily qualitatively: the peak identification table can be edited automatically or manually. The correction factor is automatically calculated, and multiple corrections can be averaged.  
Flexible peak identification and processing capabilities: Chromatographic peaks can be identified, deleted and adjusted for baseline cutting by setting parameters and time programs or manually correcting them. Ensure the accuracy of the analysis results.  
Flexible printing function: Provide result reports in fixed format and custom template format.  
Adopting technologically advanced 10/100M adaptive Ethernet communication interface, and built-in IP protocol stack, so that the instrument can easily realize long-distance data transmission through the enterprise’s internal LAN and Internet; it facilitates the establishment of the laboratory and simplifies the laboratory The configuration facilitates the management of analysis data.
The internal design of the instrument has 3 independent connection processes, which can be connected to local processing (laboratory site), unit supervisors (such as quality inspection section chiefs, production plant managers, etc.), and superior supervisors (such as environmental protection bureau, technical supervision bureau, etc.), It is convenient for the unit supervisor and superior supervisor to monitor the operation of the instrument and analyze the data results in real time.
The optional NetChromTM workstation of the instrument can support the work of multiple chromatographs at the same time, realize data processing and control, simplify document management, and reduce the user’s laboratory investment and operating costs to the greatest extent.
The system has Chinese and English operating systems, and users can switch by themselves according to their needs.
The temperature control area can be named freely by the user, which is convenient for the user to use.
The instrument adopts a multi-processor parallel working mode to make the instrument more stable and reliable; it can meet the analysis of complex samples, and can be equipped with a variety of high-performance detectors, such as FID, TCD, ECD, and FPD, and up to four detectors can be installed at the same time . Additional detectors can also be used, which makes it easy to purchase and install other detectors after the instrument is purchased.
Post time: Dec-24-2021
