GD6900 Capacitance and Dissipation Factor Tester
GD6900 metitur capacitatem et factorem dielectricae detrimenti (tgδ) instrumenti electrici altae intentionis.Integra est structura, constructo-in ponte dielectric damno test, variabilis frequentia copia potentiae aptabilis, commutator boosting et capacitor SF6 vexillum.
Princeps intentionis fons ab interno inverto instrumenti generatur, quod ad experimentum rei probatae post boost transformator adhibetur.Si poculum insulationis addere et machinam temperaturae temperare, dielectricae amissio olei insulating probetur.
●Tange LCD screen ostentus.
●Insulatio resistentiae mensurae: "instructa-in insulation resistentia test moduli, exsequi Insulation resistentiam (IR), effusio ratio (DAR), index polarizationis (PI) test.
●Calendarium chip et magna reposita intus.Salvum experimentum eventum secundum ordinem temporis, historiae recordum reprime et exitum imprime.
●Instrumentum data per orbem U exportari potest.
●Multiplices tentationis modus, cum modis intra altam intentionem, extra alta intentione, vexillum interius, vexillum externum, GST/UST, sui excitandi.Princeps intentione (plus quam 10kV) dielectricae amissionis test fieri potest in situ vexilli externi extra alta intentione.
●Test plenum signatum CVT (Capacitiva Voltage Transformer) C1 et C2 damnum dielectric et capacitas simul.Item ratio transmutationis probandi CVT et in intentione angulorum differentiae.
●Damnum dielectricum et capacitas valoris C0 in fine superiore CVT metiri possunt utendo methodo protegendi inversa.
●Signum altum celeritate sampling.Circuitus inversus et sampling intus Digitized regitur.Output voltage continenter accommodetur.
●LCR mensurae latae.Inductio, capacitas, resistentia, angulus metiri et ostendi potest.
●Multiplex praesidium de input voltage fluctuationis, output brevis circuitio, super-voltage, super-current, temperatura, secura et certa.Interim munus habet probationis fundandi, quod voltage boost pro instrumento non fundamento permittitur.
●Non opus est ut HV distraherent damnum et capacitatem dielectricorum metiendi CVT.
●Frequentia mutari potest in 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
operantes conditio | -15℃~40℃ | RH<80% | ||||||
Anti-principium impedimentum | Frequentia conversionis | |||||||
Potentia copia | AC 220V±10%, 50/60Hz | Generator adhiberi potest. | ||||||
Princeps voltage output | AC 0.5KV~ 10KV (12kV ad libitum) | omne 0.1kV | ||||||
Sagacitas | 2% | |||||||
Maximilianus.current | 200mA | |||||||
capacitas | 2000VA | |||||||
Excitatio auto-potentia | AC 0V~50V/15A | 50Hz, 60Hz una frequentia 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Dual frequency automatice | ||||||
Resolution | tgδ: 0.001% | Cx: 0.001pF | ||||||
Sagacitas | ∆tgδ: ±(1.0%+0.040%) | |||||||
∆C x: ±(1.0%+1.00PF) | ||||||||
Mensurae range | tgδ | Sine limite | ||||||
C x | 15pF < Cx < 300nF | |||||||
10KV | Cx < 60 nF | |||||||
5KV | Cx < 150 nF | |||||||
1KV | Cx < 300 nF | |||||||
CVT test | Cx < 300 nF | |||||||
LCR mensurae range | L>20H(2kV) | R>10KΩ(2kV) | ||||||
LCR mensurae accurate | 0.1% | Resolution | 0.01 | |||||
CVT ratio range | 10~10000 | |||||||
CVT ratio accurationis | 0.1% | |||||||
CVT ratio resolutionis | 0.01 | |||||||
Nulla resistentia | DC alta intentione | 5~10kV | Sagacitas | ±(%* Lectio +10V) | ||||
IR accurate | 100kΩ-1000GΩ: <5% (test intentione non minus quam 250V) 100GΩ-1000GΩ: X% (test intentione non minus quam 10000V) | |||||||
Dimension | Praecipua unitas: 350(L)×270(W)×270(H) | |||||||
Arca accessoria: 350(L)×270(W)×160(H) | ||||||||
Memoria facultatem | 200 coetus, USB repositionis orbis mico sustinetur. | |||||||
Pondus | Praecipua unitas: 22.75Kg | |||||||
Arca accessoria: 5.25Kg |
Tester | 1 set |
Accessories causa | Pars I |
HV red test plumbum 8m | Pars I |
LV nigrum test plumbum 8m | Pars I |
Potentia funis 1.8m | Pars I |
CVT Connectens plumbum 5m | Pars I |
Humus plumbi 2m | Pars I |
Print paper | 2 rotulis |
10A fuse | III pieces |
User's Guide | 1 copy |
Factory Test fama | 1 copy |
Ad libitum accessiones | |
Oleum test cellula | 1 pc* |
Heating controller | 1 pc* |
Cum cella testium olei et moderatoris calefactionis, user probare potest tan della liquoris dielectricae sicut oleum transformator.
Heating controller
Vas oleum